TLC300

Remote control RTU for MV distribution centers

Integrates the functions needed to remotely control a medium-voltage substation.

  • 1 to 16 cells
  • UPS supply 12–48 VDC
  • DNP3.0
Hardware Remote control RTU for MV distribution centers — TLC300

Every switching operation that requires sending someone out to an MV cell is lost time and avoidable risk. The TLC300 concentrates control of up to 16 cells in a single unit, with its own safety logic in each one, so opening and closing can be executed from the control center — or locally if needed — without depending on a technician on site.

  • 1 to 16 cells, without changing equipment

    Scales from a simple substation to a complex distribution center, expanding over Ethernet, RS232 or RS485.

  • Keeps operating without communication

    Each cell keeps its own local safety logic, programmable to IEC 61131-3; if the link fails, the unit keeps controlling and syncs once it's restored.

  • Everything in one unit

    Control, measurement, communication and protection concentrated in one unit, with fewer failure points than a distributed architecture.

  • Integrates with legacy or modern SCADA

    DNP3.0, MODBUS TCP/RTU and IEC 60870-5-104, as a multi-protocol gateway with no need to replace existing infrastructure.

01Technical specifications

Technical specifications

  • Control capacity

    • Controls 1 to 16 MV cells from a single unit
    • Each cell operates independently, with its own safety interlocks
    • Expandable via Ethernet, RS232 or RS485, with no system redesign
    • Configuration of 1 to 6 feeders
    • IEC 61131-3 automation programming, with user-configurable control logic
  • Motorization and control

    • 24 VDC or 48 VDC motorization, selectable per plant
    • Remote command from SCADA or local from the panel, with no central connection
    • Open/close position feedback for each controlled element
    • Full local operation on communication loss, with later synchronization
  • Communications and protocols

    • 2 RS232 ports, 1 RS485 port and 1 10/100 Mbps Ethernet port
    • LTE cellular connectivity with automatic 3G/2G fallback, dual SIM
    • Optional multi-constellation GPS
    • DNP3.0, IEC 60870-5-104 and MODBUS TCP as a slave toward the SCADA
    • MODBUS TCP, RTU and ASCII as a master toward field devices
    • Protocol gateway: concentrates and converts MODBUS to DNP3.0 or IEC 104
    • Transparent TCP bridges for each serial port
    • Remote or local configuration via web interface
  • Power, monitoring and safety

    • Integrated 12 to 48 VDC UPS supply (24 V option) on main power failure
    • Fault passage indicator per cell
    • Integrated per-cell current measurement (optional)
    • Acquisition of low-voltage variables from the control panel (optional)
    • Galvanic isolation against overvoltage and transients
    • Event history with time synchronization for auditing

02Main applications

Main applications

  • Remote control of MV distribution centers from a remote operations center
  • Urban underground networks with scattered, hard-to-reach substations
  • Reconnection and reconfiguration switching during network contingencies
  • Automating open/close sequences with interlocks
  • Migrating legacy substations to modern SCADA as a multi-protocol gateway
  • Monitoring short-circuit passage and current per cell